RC1: 'Comment on egusphere-2026-981', Anonymous Referee #1, 21 Apr 2026
- AC1: 'Reply on RC1', Maria Martinez Mendoza, 12 Jun 2026
-
RC2: 'Comment on egusphere-2026-981', Anonymous Referee #2, 13 May 2026
- AC2: 'Reply on RC2', Maria Martinez Mendoza, 12 Jun 2026
Peer review completion
AR – Author's response | RR – Referee report | ED – Editor decision | EF – Editorial file upload
AR by Maria Martinez Mendoza on behalf of the Authors (14 Jun 2026)
Author's response
Author's tracked changes
Manuscript
ED: Publish as is (29 Jul 2026) by Jason Williams
AR by Maria Martinez Mendoza on behalf of the Authors (04 Aug 2026)
Manuscript
Maria Martinez Mendoza et al.: Process-based evaluation of green roof models for assessment of heat mitigation efficacy in WRF (v4.3.1) and EnergyPlus (v8.6.0), egusphere-2026-981
General comments
This model evaluation paper compares two different green roof models for their ability to calculate the green roof surface energy balance in terms of the latent heat flux QE, the ground heat flux QG, the surface temperature (Tsurf), and substrate volumetric water content. The two models are the EnergyPLus EcoRoof formulation (ER0), a modified version of EcoRoof (ERm)and the green roof submodule of WRF (WRF-MLGR).
The analysis reveals that both models show certain biases for different reasons which are mainly related to differences in model structure and assumption. Generally, ER overestimates QE and Tsurf modestly, whereas WRF-MLGR more strongly underestimates QE but overestimates QG and Tsurf. The study clearly quantifies the deviations between model output and green roof observations from a test site in Ontario, Canada.
The paper is well written, well-structured and easy-to-follow. It presents and discusses all the mentioned terms of the surface energy balance in detail and quantifies deviations between measurements and model outputs. Hence, the paper is an important contribution to asses model performance for green roof studies in context of surface-atmosphere exchange studies, process analysis, climate change adaption studies, or urban climate research.
Specific comments
Introduction, l.58: the state-of-the-art on earlier model evaluation is fairly short. You might briefly specify which general performance those evaluations found, e.g. whether energy fluxes were over- or underestimated and to what extent.
l. 73: I suppose QH was not evaluated in your study because it could not be measured directly, right?
Methods, l.139. Due to the small dimensions of the green roof advective effects might play a role. As this was analysed in a Master Thesis (Kurukulaarachchi, 2017) which is not available to the public, could you briefly specify how advective effects were analysed in that study?
Results, l.232: Here you state that 50% of the energy are partitioned into QH. However, the sensible heat flux was not directly measured – what is calculated as a residual of the surface energy balance?
Discussion, l.437: I suggest to move the paragraph on the test of the elevated green roof module (and Fig. 12) to the results section.
Results, section 4.2.1.: I am wondering whether incorporation of specific CAM parameterisations/formulations in green roof models could (significantly) enhance model performance in term of QE and the surface energy balance representation? Could you briefly discuss that issue?
Results, l. 507. I would suggest to, in the context of green roofs, we referred to “substrates” rather than “soil,” since no actual soil is used on green roofs (they typically consist of small rock fragments, at least in most European green roofs)
Technical corrections
Fig 3: labels on x and y-axis are quite small
Fig. 4: The figure legend is hardly to read