Articles | Volume 19, issue 21
https://doi.org/10.5194/gmd-19-10735-2026
© Author(s) 2026. This work is distributed under the Creative Commons Attribution 4.0 License.
Quantifying charger-related uncertainty in electrical mobility analysis of aerosols with MPSS-UQ 1.0
Download
- Final revised paper (published on 11 Nov 2026)
- Preprint (discussion started on 18 May 2026)
Interactive discussion
Status: closed
Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor
| : Report abuse
-
RC1: 'Comment on egusphere-2026-2013', Anonymous Referee #1, 23 Aug 2026
- AC1: 'Reply on RC1', Matti Niskanen, 10 Oct 2026
-
RC2: 'Review of egusphere-2026-2013, "Quantifying charger-related uncertainty in electrical mobility analysis of aerosols with MPSS-UQ 1.0"', Anonymous Referee #2, 22 Sep 2026
- AC2: 'Reply on RC2', Matti Niskanen, 10 Oct 2026
Peer review completion
AR – Author's response | RR – Referee report | ED – Editor decision | EF – Editorial file upload
AR by Matti Niskanen on behalf of the Authors (10 Oct 2026)
Author's response
Author's tracked changes
Manuscript
ED: Publish as is (20 Oct 2026) by Xiaohong Liu
AR by Matti Niskanen on behalf of the Authors (25 Oct 2026)
I found this to be a technically rigorous manuscript that is also engaging. The authors present a Bayesian inversion approach tackling charging uncertainties for measuring aerosol particle distributions. The theoretical claims and the method all seem to be solid. I recommend prompt publication.
If there's a revision, I invite the authors to engage the following points (but no pressure if not):
- The Pfeiffer manuscript cited in support of LYF actually showed that Gatti and Kortshagen model fared better --- did you try to run that model throught your python package? On github I only see LYF and Wiedensohler as options. (Btw, list the github link itself in the acknoweldgement as well as the doi, it makes easier for people to find it)
- It would be good to compare this method against what people usually use by default (without custom inversion algorithm). For example, what would a commercial or default algorithms show for those measurements you showed in figs 9 and 10?